Description

This illustration demonstrates step one in a method designed to pass the peritoneal catheter of a ventriculoperitoneal shunt through the abdominal wall and into the peritoneal cavity through a pathway separate from the fascial and peritoneal opening. The image shows the tip of a disposable passer bent into a J shape and tunneled through the abdominal wall from the peritoneum to the subcutaneous tissue.

Project Description

I worked with neurosurgeons to describe a novel technique for passing a peritoneal catheter of a ventriculoperitoneal shunt through the abdominal wall on a path separate from the fascial opening.

Elashaal AA, Corrin M & Cusimano MD. 2010. Cerebrospinal fluid shunt insertion: techniques of peritoneal catheter placement separate from abdominal fascial and peritoneal incisions. J Neurosurg. 113(1):79-81.